DGS-3000 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
138
DGS-3000-26TC:admin#show bpdu_protection
Commands: show bpdu_protection
BPDU Protection Global Settings
---------------------------------------
BPDU Protection status : Enabled
BPDU Protection Recovery Time : 60 seconds
BPDU Protection Trap State : None
BPDU Protection Log State : None
DGS-3000-26TC:admin#
To show the bpdu_protection status ports 1-12:
DGS-3000-26TC:admin#show bpdu_protection ports 1-12
Commands: show bpdu_protection ports 1-12
Port State Mode Status
------ ------------ ----------- ----------
1 Enabled shutdown Normal
2 Enabled shutdown Normal
3 Enabled shutdown Normal
4 Enabled shutdown Normal
5 Enabled shutdown Under Attack
6 Enabled shutdown Normal
7 Enabled shutdown Normal
8 Enabled shutdown Normal
9 Enabled shutdown Normal
10 Enabled Block Normal
11 Disabled shutdown Normal
12 Disabled shutdown Normal
DGS-3000-26TC:admin#