SkyView Display Installation and Configuration
SkyView System Installation Guide - Revision AA 4-29
Configure the serial port: SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP > SERIAL
PORT x SETUP > SERIAL IN DEVICE > GARMIN / APOLLO SL40. This will automatically set the
SERIAL IN FUNCTION, SERIAL IN/OUT BAUD RATE, and SERIAL OUT DEVICE.
Set the SL40 status to be displayed on the top bar: SETUP > SYSTEM SETUP > DISPLAYED
COM > GARMIN / APOLLO SL40 (PORT x)
and
SETUP MENU > SYSTEM SETUP > DISPLAY COM IN TOP BAR: YES
Trig TY91 COM Radio
SkyView can display COM radio information from the TY91 on the top bar of the SkyView
display(s) and “push” COM frequencies to the TY91 (TUNE COM).
Connect TY91 RS232 In (TC90 Pin 6) to a SkyView serial TX. If you have more than one
SkyView display, make the same connection to all SkyView displays.
Connect TY91 RS232 Out (TC90 Pin 5) to a SkyView serial RX. If you have more than one
SkyView display, make the same connection to all SkyView displays.
Ensure there is a shared ground between the SkyView display and the TY91. If you have
more than one SkyView display, make the same connection to all SkyView displays.
On the TY91, configure the serial port appropriately (per Trig’s documentation).
On SkyView
SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP > SERIAL PORT x SETUP > SERIAL IN
DEVICE > TRIG TY91. This will automatically set the SERIAL IN FUNCTION, SERIAL IN/OUT
BAUD RATE, and SERIAL OUT DEVICE.
SETUP MENU > SYSTEM SETUP > PRIMARY COM > TRIG TY91 (PORT x)
SETUP MENU > SYSTEM SETUP > DISPLAY COM IN TOP BAR > YES
Icom IC-A210 COM Radio
The IC-A210 does not transmit status or frequencies via serial port, so IC-A210 information
cannot be displayed on the top bar of the SkyView display(s). SkyView can send COM radio
frequencies to the IC-A210 (TUNE COM).
Confirm that your A210 is running Software version 1.53 or newer. This feature will not
work with old Software. Contact Icom for details on upgrading your radio Software.
Connect IC-A210 serial RX (Molex Pin 2 / D15 Pin 10) to a SkyView serial TX. If you have
more than one SkyView display, make the same connection to all SkyView displays.
Ensure there is a shared ground between the SkyView display and the IC-A210. If you have
more than one SkyView display, make the same connection to all SkyView displays.
On the IC-A210, configure the serial port appropriately (per Icom documentation).
On SkyView
SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP > SERIAL PORT x SETUP > SERIAL IN
DEVICE > ICOM A210. This will automatically set the SERIAL IN FUNCTION, SERIAL IN/OUT