SkyView Display Installation and Configuration
4-30 SkyView System Installation Guide - Revision AA
BAUD RATE, and SERIAL OUT DEVICE. (Although there is no IC-A210 serial TX to SkyView
serial RX connection, SERIAL IN DEVICE must be configured as described.)
SETUP MENU > SYSTEM SETUP > PRIMARY COM > ICOM A210 (PORT x)
and
SETUP MENU > SYSTEM SETUP > DISPLAY COM IN TOP BAR > NO
MGL Avionics V6/V10 COM Radio
The V6 and V10 do not transmit status or frequencies via serial port, so V6/V10 information
cannot be displayed on the top bar of the SkyView display(s). SkyView can send COM radio
frequencies to the V6/V10 (TUNE COM).
Connect V6/V10 RS232 DATA1 - IN (D25 Pin 3) to a SkyView serial TX. If you have more than
one SkyView display, make the same connection to all SkyView displays.
Ensure there is a shared ground between the SkyView display and the V6/V10. If you have
more than one SkyView display, make the same connection to all SkyView displays.
On the V6/V10, configure the serial port appropriately (per MGL Avionics’ documentation).
On SkyView
SETUP MENU > SYSTEM SETUP > SERIAL PORT SETUP > SERIAL PORT x SETUP > SERIAL IN
DEVICE > MGL V6/V10. This will automatically set the SERIAL IN FUNCTION, SERIAL IN/OUT
BAUD RATE, and SERIAL OUT DEVICE. (Although there is no V6/V10 serial TX to SkyView
serial RX connection, SERIAL IN DEVICE must be configured as described.)
SETUP MENU > SYSTEM SETUP > PRIMARY COM > MGL V6/V10 (PORT x)
and
SETUP MENU > SYSTEM SETUP > DISPLAY COM IN TOP BAR > NO
f.u.n.k.e. Avionics ATR833 8.33 kHz-capable COM Radio
Garmin GTR 200
Garmin GTR 225 COM Radio
Garmin GNC 255 COM Radio / NAV Receiver
SkyView can send frequencies to the GNC 255’s standby frequency.
On the GNC 255:
Connect GNC 255 P2001 Pin 16 to a SkyView serial TX. If you have more than one
SkyView display, make the same connection to all SkyView displays.
Connect GNC 255 P2001 Pin 1 to a SkyView serial RX. If you have more than one
SkyView display, make the same connection to all SkyView displays.
Ensure there is a shared ground between the SkyView display and the GNC 255. If you
have more than one SkyView display, make the same connection to all SkyView displays.
On the GNC 255, configure the serial port:
o Set “I/O Mode” to “NMEA”
o Set “CDI Indicator” to “NONE”