Location 410 – 411 Page 216
Entry Timer 1
Location 412 – 413 Page 216
Entry Timer 2
Location 414 – 415 Page 217
Exit Time
Location 416 – 417
Page 217
Entry Guard Time For STAY Mode
Location 418 – 419 Page 217
Delay Alarm Reporting Time
Location 420 - 421 Page 218
Sensor Watch Time
Location 422 Page 218
Codepad Lockout Time
Location 423
Page 219
Siren Run Time
Location 424 Page 219
Siren Sound Rate (Slow <-Sound-> Fast)
Location 425 Page 220
Auto Arming Pre-Alert Time
Location 426 – 429 Page 220
Auto Arming Time
Location 430 - 433 Page 221
Auto Disarming Time
Location 434 Page 221
Kiss-Off Wait Time
Location 435 Page 221
Speaker Beep Volume
Location 436
Page 227
System Options 1
Location 437 Page 228
System Options 2
Location 438 Page 229
System Options 3
Location 439 Page 230
System Options 4
Location 410 Increments Of 1 Second (0 - 15 Sec’s)
Location 411 Increments Of 16 Seconds (0 - 240 Sec’s)
41
Location 412 Increments Of 1 Second (0 - 15 Sec’s)
Location 413 Increments Of 16 Seconds (0 - 240 Sec’s)
82
Location 414 Increments Of 1 Second (0 - 15 Sec’s)
Location 415 Increments Of 16 Seconds (0 - 240 Sec’s)
12 3
00
Location 416 Increments Of 1 Second (0 - 15 Sec’s)
Location 417 Increments Of 16 Seconds (0 - 240 Sec’s)
00
Location 418 Increments Of 1 Second (0 - 15 Sec’s)
Location 419 Increments Of 16 Seconds (0 - 240 Sec’s)
Location 420 Increments Of Days (Tens Digit)
Location 421 Increments Of Days (Units Digit)
00
0
Location 422 Increments Of 10 Seconds
5
Location 423 Increments Of 1 Minute (0 – 15 Min’s)
7
Location 425 Increments Of 5 Minutes
1
Location 426 Hour Of The Day (Tens Digit)
Location 427 Hour Of The Day (Units Digit)
Location 428 Minute Of The Day (Tens Digit)
Location 429 Minute Of The Day (Units Digit)
0 0 0
Location 430 Hour Of The Day (Tens Digit)
Location 431 Hour Of The Day (Units Digit)
Location 432 Minute Of The Day (Tens Digit)
Location 433 Minute Of The Day (Units Digit)
0 0 0
3
Location 434 Increments Of 500 ms (500 ms – 8 Sec’s)
13
Location 435 0 = No Beeps / 15 = Loudest Beeps
1
1 = EDM Smart Lockout Allowed
2 = Horn Speaker Monitor
4 = Strobe Indications For Radio Arm/Disarm
8 = Assign Button 4 On Transmitter To Operate STAY Mode 1
1 = Codepad Panic To Be Silent
2 = Codepad Fire To Be Silent
4 = Codepad Medical To Be Silent
8 = Access Denied To Be Silent
0
1 = AC Fail After 1 Hour (Disabled = After 2 Minutes)
2 = Ignore AC Fail
4 = Pulse Count Handover Allowed
8 = Handover Delay To Be Sequential
8
0
1 = Panel To Power Up Disarmed (If Power Reset)
2 = Arm/Disarm Tracking On Power Up
4 = Internal Crystal To Keep Time
8 = Keyswitch Interface, Night Arm Station Or RE005 Installed
292 Solution Ultima 844/862/880 Installation Manual
ISSUE162.DOC Electronics Design and Manufacturing Pty Limited
0
0