Enty Type Severity
Service
Aected
Direcon Locaon Descripon
AC00-F011 minor non–service-
aecng
n/a NEND Mismatch of Equipment and Aributes:
TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■ A Fan unit is mismounted.
■ A Fan unit slot is not provisioned
correctly.
1. Remove and remount the Fan unit.
2. Correct the Fan unit slot provisioning.
BDL1-3B11, BDL1-3R11,
1GEX, 1GEBT
major non–service-
aecng
n/a NEND Interblade communicaon Miscabled
Connecon: TYPE = <unit type>
Probable Cause Suggested Correcve Acon
The interblade communicaon cables are
not installed correctly.
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
PIL1-3PS2 warning non–service-
aecng
n/a NEND Mismatch of Equipment and Aributes:
TYPE=<unit type> and the admin-status is
down
Probable Cause Suggested Correcve Acon
■ The PIU installed in the specied slot is
mismounted.
■ The PIU does not match the slot for
which it is provisioned.
1. Remove and remount the PIU module.
2. Replace the PIU module with the correct PIU module.
PIL1-3PS2 minor non–service-
aecng
n/a NEND Mismatch of Equipment and Aributes:
TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■ The PIU installed in the specied slot is
mismounted.
■ The PIU does not match the slot for
which it is provisioned.
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
BDL1-3B11, BDL1-3R11,
1GEX, 1GEBT
major non–service-
aecng
n/a NEND Interblade communicaon Miscabled
Connecon: TYPE = <unit type>
Probable Cause Suggested Correcve Acon
The interblade communicaon cables are
not installed correctly.
1. Remove and remount the PIU.
2. Replace the PIU with the correct PIU.