Enty Type Severity
Service
Aected
Direcon Locaon Descripon
100ME minor non–service-
aecng
n/a NEND Mismatch of Equipment and Aributes:
TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■ The SFP module installed in the
specied port is mismounted.
■ The SFP module does not match the
port for which it is provisioned.
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
100ME crical service-
aecng
n/a NEND Mismatch of Equipment and Aributes:
TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■ The SFP module installed in the
specied port is mismounted and has an
interface provisioned on it.
■ The SFP module does not match the
port for which it is provisioned and has
an interface provisioned on it.
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
1GEBT warning non–service-
aecng
n/a NEND Mismatch of Equipment and Aributes:
TYPE=<unit type> and the admin-status is
down
Probable Cause Suggested Correcve Acon
■ The SFP module installed in the
specied port is mismounted.
■ The SFP module does not match the
port for which it is provisioned.
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
1GEBT minor non–service-
aecng
n/a NEND Mismatch of Equipment and Aributes:
TYPE=<unit type>
Probable Cause Suggested Correcve Acon
■ The SFP module installed in the
specied port is mismounted.
■ The SFP module does not match the
port for which it is provisioned.
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
BDL1-3B11, BDL1-3R11,
1GEX, 1GEBT
major non–service-
aecng
n/a NEND Interblade communicaon Miscabled
Connecon: TYPE = <unit type>
Probable Cause Suggested Correcve Acon
The interblade communicaon cables are
not installed correctly.
1. Remove and remount the SFP module.
2. Replace the SFP module with the correct SFP module.
System Maintenance
Trouble Clearing
307
Release 19.1.1 · Issue 1.1, May 2021
Fujitsu and Fujitsu Customer Use Only