Enty Type Severity
Service
Aected
Direcon Locaon Descripon
Port (Edge) crical service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
edge port is too high.
Check the opcal receive power at the indicated port.
Port (Client) crical service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
client port is too high.
Check the opcal transmit power at the indicated port.
Port (Client) crical service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
client port is too high.
Check the opcal receive power at the indicated port.
Port (OSC) major non–service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
OSC port is too high.
Check the opcal receive power at the indicated port.
1GEX minor non–service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEX interface is too high.
None
1GEX minor non–service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
1GEX interface is too high.
Check the opcal receive power at the indicated port.
System Maintenance
Trouble Clearing
326