Enty Type Severity
Service
Aected
Direcon Locaon Descripon
1GEX crical non–service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEX interface is too high.
None
1GEX crical non–service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
1GEX interface is too high.
Check the opcal receive power at the indicated port.
1GEBT minor non–service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEBT interface is too high.
Check the opcal transmit power at the indicated port.
1GEBT minor non–service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
1GEBT interface is too high.
Check the opcal receive power at the indicated port.
1GEBT crical non–service-
aecng
transmit NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated transmit
1GEBT interface is too high.
Check the opcal transmit power at the indicated port.
1GEBT crical non–service-
aecng
receive NEND Power Out of Specicaon–High: TYPE =
<unit type>
Probable Cause Suggested Correcve Acon
The opcal power on the indicated receive
1GEBT interface is too high.
Check the opcal receive power at the indicated port.
System Maintenance
Trouble Clearing