Chapter 5 Memory and Parameter
Even when the parameter value is set to '1: detect', if the software upper limit/lower limit is set to the initial value (upper limit:
2,147,483,647, lower limit: -2,147,483,648) or the same value, software limit is not detected.
11) JOG high speed / JOG low speed
Jog speed is related to the speed when operating jog which is a type of manual operation. Jog operation is divided into JOG
high speed and JOG low speed.
Jog is operated in the pattern with the areas of acceleration, fixed speed, and deceleration. Therefore, the acceleration area
is controlled by jog acceleration time and the deceleration area is controlled by jog deceleration time.
Setting range of JOG high speed cannot exceed the speed limit. Also, JOG high speed must be the same with or bigger
than JOG low speed.
12) JOG acceleration, JOG deceleration, JOG jerk
Set the values of acceleration, deceleration, and jerk which are applied in the case of JOG high speed and JOG low speed
operation.
If JOG acceleration is 0, it is operated immediately at JOG set speed without acceleration area at the beginning of JOG
operation.
If JOG deceleration is 0, it is stopped immediately at 0 without deceleration area at the stop of JOG operation.
If JOG jerk is 0, the form of acceleration/deceleration is in a linear as acceleration is fixed
(c) NC parameters
It describes the NC parameters of the axis parameters.
Identifying range to reach the
spindle rotation command
Determine whether or not the command
speed of the spindle axis is reached by the
0~100% 95%
Identifying RPM to reach the
spindle rotation zero speed
Determine whether or not the zero speed of
the spindle axis is reached by the set value.
0~100rpm 5rpm