Chapter 9 NC Control Function
9) Enable/Disable stroke function (G22, G23)
G22 (X_ Y_ Z_) (I_ J_ K_)
G23
G22: Stroke check function On
G23: Stroke check function Off
X_ Y_ Z_: Enter the lower limit position based on the machine origin of each coordinate.
I_ J_ K_: Enter the upper limit position based on the machine origin of each coordinate.
This command sets the Soft Limit of the coordinate system. You can input the lower limit coordinate (X, Y, Z) and
upper limit coordinate (I, J, K) of each stroke. If it is out of this range, the error will be displayed. Then, in a manual
mode, it can be entered into the working area or be driven after turning off the stroke check function. This is a
modal command so it continues to be valid once it is commanded.
For A, B, C, U, V, W, S axes other than X, Y and Z axes, it should be set by the parameters. At this time, the
parameter, „Whether to use G22 No Travelling Area‟ should be set to 1 to use the G22 command.