Chapter 9 NC Control Function
Set the upper speed limit
of the cutting feed
If the cutting speed exceeding the set value is
commanded, the cutting speed is limited to the set
value and an alarm occurs.
(0 ~ 100,000 unit/min, real number)
Set the lower speed limit
of the cutting feed
It is applied only when the cutting speed is not
commanded in the feed mode per minute.
(0 ~ 100,000 unit/min, real number)
Acceleration /
deceleration method of
the interpolation operation
1: Acceleration / deceleration before interpolation
Operating method of the
continuous blocks for
acceleration /
deceleration before
interpolation
When executing the consecutive blocks, it creates
the connecting trajectory that draws an arc on the
corner of the connecting trajectory with the speed
set with the next block. 1: When it is set to
Buffered, the circular arc is not inserted.
1: Buffered
2: Blending Low
3: Blending Previous
4: Blending Next
5: Blending High
Acceleration at the time of
cutting feed (before
interpolation)
Acceleration at the time of cutting feed
Deceleration at the time
of cutting feed (before
interpolation)
Deceleration at the time of cutting feed
Jerk at the time of cutting
feed (before interpolation)
Jerk at the time of cutting feed