Chapter 9 NC Control Function
2.Channel/Axis
parameters
The set value is used as the traverse speed of the
G00 block.
(0~100000 unit/min, real number)
Minimum value of the
G22 Traverse-
Prohibited Area range
for the X, Y, and Z axis.
Set the minimum value of the G22 Traverse-
Prohibited Area range for the X, Y, and Z axis.
(-100,000~100,000 unit, real number)
Maximum value of the
G22 Traverse-
Prohibited Area range
for the X, Y, and Z axis.
Set the maximum value of the G22 Traverse-
Prohibited Area range for the X, Y, and Z axis.
(-100,000~100,000 unit, real number)
Minimum value of the
3
rd
Traverse-Prohibited
Area range for the X, Y,
and Z axis.
Set the minimum value of the 3
rd
Traverse-
Prohibited Area range for the X, Y, and Z axis.
(-100,000~100,000 unit, real number)
Maximum value of the
3
rd
Traverse-Prohibited
Area range for the X, Y,
and Z axis.
Set the maximum value of the 3
rd
Traverse-
Prohibited Area range for the X, Y, and Z axis.
(-100,000~100,000 unit, real number)
Overrun feed rare of
single direction
positioning
Set the overrun feed rate of the 9 axes; X, Y, Z, A,
B, C, U, V, W when using the single direction
positioning function (G60).
After stopping at the position separated by the set
value for the G60 command block‟s axis, it moves
to the command position to eliminate the effect of
backlash.