215184 449 Revision A
Figure 9.320: John Deere Combine Display
8. Press and hold REEL RAISE switch until reel is fully raised.
Continue holding REEL RAISE switch until prompted by the
display.
Figure 9.321: John Deere Combine Display
9. When all steps have been completed, CALIBRATION
COMPLETE message is displayed on the screen. Exit the
CALIBRATION menu by pressing ENTER icon (A).
NOTE:
If an error code appears during calibration, the sensor is out
of voltage range and will require adjustment. For
instructions, refer to Checking Reel Height Sensor Voltages
– John Deere S and T Series, page 445.