EasyManuals Logo

Olympus 38DL PLUS User Manual

Olympus 38DL PLUS
318 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #5 background imageLoading...
Page #5 background image
DMTA-10004-01EN, Rev. D, November 2016
Table of Contents
v
5.2.1 Calibrating the Instrument ........................................................................... 67
5.2.2 Test Blocks ....................................................................................................... 70
5.2.3 Transducer Zero Compensation .................................................................. 70
5.2.4 Material Sound Velocity and the Zero Calibrations ................................. 71
5.2.5 Entering a Known Material Sound Velocity .............................................. 72
5.2.6 Locked Calibrations ....................................................................................... 73
5.2.7 Factors Affecting the Performance and the Accuracy .............................. 73
5.3 Measuring Thicknesses ............................................................................................ 75
5.4 Saving Data ................................................................................................................ 76
5.5 Measurements with THRU-COAT D7906 and D7908 Transducers .................. 78
5.5.1 Enabling the THRU-COAT Function .......................................................... 78
5.5.2 Performing a THRU-COAT Calibration ..................................................... 79
5.6 Echo Detection Modes with Dual Element Transducers ..................................... 80
5.6.1 Blanking Adjustments in Manual Echo-to-Echo Detection Mode .......... 83
5.6.2 Dual Element Transducer Selection in Echo-to-Echo Modes .................. 84
5.6.3 Echo-to-Echo Mode Datalogger Flags ......................................................... 85
5.7 Using the VGA Output ............................................................................................ 86
6. Using EMAT Transducers ......................................................................... 87
6.1 Connecting the E110-SB EMAT Transducer .......................................................... 88
6.2 Calibrating with the E110-SB EMAT Transducer ................................................. 89
7. Software Options ....................................................................................... 91
7.1 Activating Software Options ................................................................................... 92
7.2 High Resolution Software Option .......................................................................... 93
7.3 Oxide Layer Software Option ................................................................................. 93
7.3.1 Steam Boiler Tube Scale ................................................................................. 94
7.3.2 Setting Up for Oxide Layer Measurement ................................................. 95
7.3.3 Calibrating for Oxide Layer Measurement ................................................ 96
7.3.4 Measuring Boiler Tube and Oxide Layer Thicknesses ............................. 97
7.4 Multi-Measurement Software Option .................................................................... 99
7.4.1 Active Measurement .................................................................................... 100
7.4.2 Using the Multi-Measurement Normal Mode ......................................... 100
7.4.3 Using the Multi-Measurement with the Soft Contact Mode ................. 102
7.4.4 Using the Multi-Measurement % Total Thickness Mode ....................... 104
7.5 Encoded B-Scan Option ......................................................................................... 105
7.6 High Penetration Software Option ....................................................................... 111
8. Using Special Functions ......................................................................... 113
8.1 Activating and Configuring a Differential Mode ............................................... 113
8.2 Using the Minimum, Maximum, or Min/Max Thickness Mode ...................... 115

Table of Contents

Other manuals for Olympus 38DL PLUS

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Olympus 38DL PLUS and is the answer not in the manual?

Olympus 38DL PLUS Specifications

General IconGeneral
Operating Temperature-10 °C to 50 °C (14 °F to 122 °F)
Data LoggerYes
InterfaceUSB, RS-232
Thickness Range0.08 mm to 635 mm (0.003 in. to 25 in.) depending on material and transducer
DisplayBacklit LCD
Battery TypeThree alkaline or NiMH AA cells
PulserAdjustable square wave pulser
Receiver Bandwidth0.5 MHz to 20 MHz
LanguagesEnglish, French, German, Spanish, Italian, Russian, Japanese, Chinese
Resolution0.001 mm or 0.0001 in.
Transducer Frequency2 MHz to 30 MHz
MaterialPlastic housing