11.12 o: KEYPAD
384 SIEPCYEUOQ2V01A Q2V Technical Manual
o3: COPY FUNCTION
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o3-01
(0515)
COPY Keypad Selection
of Mode
Sets the function that saves and copies drive parameters to a different drive with the
keypad.
0 : Copy Select
1 : Bck (Drive->OPE)
2 : Res (OPE->Drive)
3 : Verify (Check)
4 : Del (Clear OPE Memory)
0
(0 - 4)
705
o3-02
(0516)
COPY Allow Selection
Sets the copy function when o3-01 = 1 [COPY Keypad Selection of Mode = Bck
(Drive->OPE)].
0 : Disabled
1 : Enabled
0
(0, 1)
705
o3-04
(0B3E)
COPY Memory
Selection
Sets the storage location for drive parameters when you back up and restore parameters.
This parameter is only available when using an LCD keypad.
0 : Memory 1
1 : Memory 2
2 : Memory 3
3 : Memory 4
0
(0 - 3)
705
o3-05
(0BDA)
COPY Items Selection
Sets which parameters are backed up, restored, and referenced. This parameter is only
available when using an LCD keypad.
0 : Std
1 : Std+Solution
0
(0, 1)
705
o3-06
(0BDE)
AutoBackup Selection
Sets the function that automatically backs up parameters. This parameter is only
available when using an LCD keypad.
0 : Disabled
1 : Enabled
1
(0, 1)
706
o3-07
(0BDF)
AutoBackup Lapse
Sets the interval at which the automatic parameter backup function saves parameters
from the drive to the keypad.
Note:
This parameter is only available when using an LCD keypad.
1 : 10 minutes
2 : 30 minutes
3 : 60 minutes
4 : 12 hours
2
(1 - 4)
706
o4: MAINTENANCE MONITORS
No.
(Hex.)
Name Description
Default
(Range)
Ref.
o4-01
(050B)
Cum.Oper TimeSetting
Sets the initial value of the cumulative drive operation time in 10-hour units.
0 h
(0 - 9999 h)
706
o4-02
(050C)
Cum.Oper TimeSelect
Sets the condition that counts the cumulative operation time.
1 : Log Power-On Time
2 : Log Run Time
1
(1, 2)
707
o4-03
(050E)
Fan.Oper Setting
Sets the value from which to start the cumulative drive cooling fan operation time in 10-
hour units.
0 h
(0 - 9999 h)
707
o4-05
(051D)
Cap.Maint.Setting
Sets the U4-05 [Capacitor Maintenance] monitor value.
0%
(0 - 150%)
707
o4-07
(0523)
PreChgRly Preset
Maintenance Cnt
Sets the U4-06 [SoftChgRelay Maint] monitor value.
0%
(0 - 150%)
707
o4-09
(0525)
IGBT Preset
Maintenance Cnt
Sets the U4-07 [IGBT Maintenance] monitor value.
0%
(0 - 150%)
707
o4-11
(0510)
Flt.History Initialization
Resets the records of Monitors U2: FAULT and U3: FAULT HISTORY.
0 : No Reset
1 : Reset
0
(0, 1)
708