10.5 Model Specifications (Three-Phase 400 V Class)
296 SIEPCYEUOQ2V01A Q2V Technical Manual
10.5 Model Specifications (Three-Phase 400 V Class)
Table 10.6 Ratings (Three-Phase 400 V Class)
Model Duty Rating 4001 4002 4004 4005 4007 4009 4012
Maximum Applicable Motor
Output
*1
(kW)
HD 0.37 0.55 1.1 1.5 2.2 3.0 4.0
ND 0.37 0.75 1.5 2.2 3.0 4.0 5.5
Maximum Applicable Motor
Output
*1
(HP)
HD 1/2 3/4 2 3 3 4 5
ND 1/2 1 2 3 4 5 7.5
Input
Rated Input
Current (A)
HD 1.2 1.8 3.2 4.4 6.0 8.2 10.4
ND 1.2 2.1 4.3 5.9 8.1 9.4 14
Output
Rated Output
Capacity
*2
(kVA)
HD 0.9 1.4 2.6 3.7 4.3 5.6 7
ND 0.9 1.6 3.1 4.1 5.4 6.8 9.1
Rated Output
Current (A)
HD 1.2 1.8 3.4 4.8 5.6 7.3 9.2
ND 1.2 2.1 4.1 5.4 7.1 8.9 11.9
Overload Tolerance
• HD: 150% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10 minutes.
• ND: 110% of the rated output current for 60 seconds. The permitted frequency of overload is once every 10 minutes.
Note:
Derating may be necessary for applications that start and stop frequently.
Carrier Frequency
HD: 8 kHz without derating the drive capacity.
ND: 2 kHz without derating the drive capacity.
Derate the drive capacity to use values to 15 kHz maximum.
Maximum Output Voltage
Three-phase 380 V to 480 V
Note:
The maximum output voltage is proportional to the input voltage.
Maximum Output Frequency
• V/f Control, OLVector, PM OLVector: 590 Hz
• PM AOLVector: 270 Hz
• EZ Vector: 120 Hz
Measures for
Harmonics
DC reactor External options
Braking Device Braking Transistor Standard internal characteristics
EMC Filter
EMC Filter
IEC61800-3
Category C2 (Conducted emission)
Power Supply
Rated Voltage/Rated Frequency Three-phase AC power supply 380 V to 480 V at 50/60 Hz
Permitted Voltage Fluctuation -15% to +10%
Permitted Frequency Fluctuation ±5%
Input Power
(kVA)
HD
1.1 1.6 2.9 4 5.5 7.5 9.5
ND
1.1 1.9 3.9 5.4 7.4 8.6 13
*1 The maximum applicable motor output complies with 380 V motor ratings as specified in Annex G of IEC 60947-4-1. The rated
output current of the drive output amps must be equal to or more than the motor rated current.
*2 The rated output capacity is calculated with a rated output voltage of 440 V.
Table 10.7 Ratings (Three-Phase 400 V Class)
Model Duty Rating 4018 4023 4031 4038 4044 4060
Maximum Applicable Motor Output
*1
(kW)
HD 5.5 7.5 11.0 15.0 18.5 22.0
ND 7.5 11.0 15.0 18.5 22.0 30.0
Maximum Applicable Motor Output
*1
(HP)
HD 10 10 15 20 25 30
ND 10 15 20 25 30 40
Input
Rated Input
Current (A)
HD 15 20 29 39 50.5 59.7
ND 20 24 38 44 59.7 80.7