3 - 39
3 Operation
High-function General-purpose Inverter RX2 Series User’s Manual
3-8 Parameter Function
3
3-8-2 Limiting Displayed Parameters
(j) Brake control 1 (Forward/reverse set individually)
Display condition: AF*30 = 02
(k) Brake control 2
Display condition: AF*30 = 03
(l) Free electronic thermal
Display condition: bc*11 = 02
(m) Gain mapping 1
Display condition: HA*20 = 00
(n) Gain mapping 2
Display condition: HA*20 = 01
Parameter Name
AF*38 * brake release establishment waiting time (reverse rotation)
AF*39 * acceleration waiting time (reverse rotation)
AF*40 * stop waiting time (reverse rotation)
AF*41 * brake check waiting time (reverse rotation)
AF*42 * brake release frequency (reverse rotation)
AF*43 * brake release current (reverse rotation)
AF*44 * brake apply frequency (reverse rotation)
Parameter Name
AF*50 * brake release delay time
AF*51 * brake apply delay time
AF*52 * brake check time
AF*53 * servo lock time at start
AF*54 * servo lock time at stop
Parameter Name
bC*20 * free electronic thermal frequency 1
bC*21 * free electronic thermal current 1
bC*22 * free electronic thermal frequency 2
bC*23 * free electronic thermal current 2
bC*24 * free electronic thermal frequency 3
bC*25 * free electronic thermal current 3
Parameter Name
HA*21 * gain switch time
HA*27 * gain mapping P control P gain 1
HA*30 * gain mapping P control P gain 2
Parameter Name
HA*22 * gain switch intermediate speed 1
HA*23 * gain switch intermediate speed 2
HA*24 * gain mapping maximum speed
HA*31 * gain mapping P gain 3
HA*32 * gain mapping I gain 3
HA*33 * gain mapping P gain 4
HA*34 * gain mapping I gain 4

Table of Contents