9 Communications Functions
9 - 36
High-function General-purpose Inverter RX2 Series User’s Manual
0501h Retry monitor 5 Factor
dE-35 R
1 to 255 1
0502h 0501h
Retry monitor 5 Output fre-
quency
-59000 to 59000 0.01(Hz)
0503h 0502h (with sign)
0504h 0503h
Retry monitor 5 Output cur-
rent
0 to 65535 0.01(A)
0505h 0504h
Retry monitor 5 P-N DC volt-
age
0 to 10000 0.1(Vdc)
0506h 0505h
Retry monitor 5 Inverter
state
0 to 8
*5
1
0507h 0506h Retry monitor 5 LAD state
0 to 5
*5
1
0508h 0507h
Retry monitor 5 INV control
mode
0 to 11
*5
1
0509h 0508h Retry monitor 5 Limit state
0 to 6
*5
1
050Ah 0509h Retry monitor 5 Special state
0 to 6
*5
1
050Ch 050Bh Retry monitor 5 RUN time
0 to 1000000 1(hr)
050Dh 050Ch
050Eh 050Dh
Retry monitor 5 Power ON
time
0 to 1000000 1(hr)
050Fh 050Eh
0510h 050Fh
Retry monitor 5 Absolute
time (year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
0511h 0510h
Retry monitor 5 Absolute
time (day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
0512h 0511h
Retry monitor 5 Absolute
time (hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-
0515h 0514h Retry monitor 6 Factor
dE-36 R
1 to 255 1
0516h 0515h
Retry monitor 6 Output fre-
quency
-59000 to 59000 0.01(Hz)
0517h 0516h (with sign)
0518h 0517h
Retry monitor 6 Output cur-
rent
0 to 65535 0.01(A)
0519h 0518h
Retry monitor 6 P-N DC volt-
age
0 to 10000 0.1(Vdc)
051Ah 0519h
Retry monitor 6 Inverter
state
0 to 8
*5
1
051Bh 051Ah Retry monitor 6 LAD state
0 to 5
*5
1
051Ch 051Bh
Retry monitor 6 INV control
mode
0 to 11
*5
1
051Dh 051Ch Retry monitor 6 Limit state
0 to 6
*5
1
051Eh 051Dh Retry monitor 6 Special state
0 to 6
*5
1
0520h 051Fh Retry monitor 6 RUN time
0 to 1000000 1(hr)
0521h 0520h
0522h 0521h
Retry monitor 6 Power ON
time
0 to 1000000 1(hr)
0523h 0522h
0524h 0523h
Retry monitor 6 Absolute
time (year, month)
00 to 99 (BCD code)
01 to 12 (BCD code)
-
0525h 0524h
Retry monitor 6 Absolute
time (day, day of the week)
01 to 31 (BCD code)
00 to 06 (BCD code)
-
0526h 0525h
Retry monitor 6 Absolute
time (hour, minute)
00 to 23 (BCD code)
00 to 59 (BCD code)
-