2 - 37
2 Design
High-function General-purpose Inverter RX2 Series User’s Manual
2-3 Wiring
2
2-3-4 Wiring for Main Circuit Terminals
* The EMC filter is enabled/disabled by switching the short circuit bar.
3G3RX2-A2370
R0,T0 : M4
Earth terminal: M8
Others: M8
* The EMC filter is enabled/disabled by switching the short circuit bar.
3G3RX2-A4370
R0,T0 : M4
Earth terminal: M8
Others: M8
Arrangement of Terminals Model
R0 T0
R
(L1)
S
(L2)
T
(L3)
U
(T1)
V
(T2)
W
(T3)
PD
(+1)
P
(+)
N
(-)
G
G
Short circuit connector
for EMC filter
Disable
Charge lamp
(Light when
electricity turned on)
Enable
Power supply input wire Motor output wire
PD-P short bar
Switching
(screw switching)
R0 T0
R
(L1)
S
(L2)
T
(L3)
U
(T1)
V
(T2)
W
(T3)
PD
(+1)
P
(+)
N
(-)
RB
(RB)
G
G
Short circuit connector
for EMC filter
Disable
Enable
Power supply input wire
Motor output wire
PD-P short bar
Charge lamp
(Light when
electricity turned on)