HAVE QUICK Input: Edit Window
To configure the settings of the HAVE QUICK Input (also referred to as ‘Reference’), go
to its Edit window. For instructions, see: "Configuring Option Card Inputs/Outputs" on
page336.
The Web UI list entry for this card is: HAVE QUICK In/Out.
The input is named: HQ Input [number].
The Edit window allows the configuration of the following settings:
Format: Used to configure the formatting of the four available HAVE QUICK out-
puts. The available output formats are as follows:
STANAG 4246 HQ I
STANAG 4246 HQ II
STANAG 4430 STM
STANAG 4430 Ext HQ
ICD-GPS-060A BCD
ICD-GPS-060A HQ
DOD-STD-1399 BCD
Timescale: Used to select the time base for the incoming time code data. The
entered Timescale is used by the system to convert the time in the incoming data
stream to UTC time for use by the System Time. The available choices are:
UTC: Coordinated Universal Time ("temps universel coordonné"), also
referred to as ZULU time
440 SecureSync 2400 User Manual
APPENDIX