EasyManua.ls Logo

Orolia SecureSync 2400 - Page 457

Default Icon
589 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
TAI: Temps Atomique International
GPS: The raw GPS time as transmitted by the GNSS satellites (as of 15-Febru-
ary-2021, this is 18 seconds ahead of UTC time)
Offset: Provides the ability to account for HAVE QUICK cable delays or other
latencies in the HAVE QUICK outputs. The Offset values are entered in nano-
seconds (ns). The available Offset range is –500 to +500 ms.
HAVE QUICK Input: Status Window
To view the current settings of the HAVE QUICK Input (also referred to as ‘Reference’),
go to its Status window. For instructions, see: "Viewing Input/Output Configuration Set-
tings" on page334.
The Web UI list entry for this card is: HAVE QUICK In/Out.
The input is named: HQ Input [number].
The Status window displays the following settings:
Reference ID: Indicates the letters used in the Input Reference Priority table for this
particular input reference.
Validity: [TIME, PPS] Indicates the validity of the Time input and the PPS input. If
the input signal is valid the indicator will be green. If the signal is not valid, the indic-
ator will be orange.
Format: Used to configure the formatting of the four available HAVE QUICK out-
puts. The available output formats are as follows:
SecureSync 2400 User Manual 441