STANAG 4246 HQ I
STANAG 4246 HQ II
STANAG 4430 STM
STANAG 4430 Ext HQ
ICD-GPS-060A BCD
ICD-GPS-060A HQ
DOD-STD-1399 BCD
Timescale: Used to select the time base for the incoming time code data. The
entered Timescale is used by the system to convert the time in the incoming data
stream to UTC time for use by the System Time. The available choices are:
UTC: Coordinated Universal Time ("temps universel coordonné"), also
referred to as ZULU time
TAI: Temps Atomique International
GPS: The raw GPS time as transmitted by the GNSS satellites (as of 15-Febru-
ary-2021, this is 18 seconds ahead of UTC time).
Offset: Provides the ability to account for HAVE QUICK cable delays or other laten-
cies in the HAVE QUICK outputs. The Offset values are entered in nanoseconds
(ns). The available Offset range is –500 to +500 ms.
TFOM: The Time Figure of Merit for the input.
HAVE QUICK Output: Edit Window
To configure the settings of a HAVE QUICK Output, go to its Edit window. For instruc-
tions, see: "Configuring Option Card Inputs/Outputs" on page336.
The Web UI list entry for this card is: HAVE QUICK In/Out.
Outputs are named: HQ Output [number].
442 SecureSync 2400 User Manual
APPENDIX

Table of Contents

Other manuals for Orolia SecureSync 2400