Plockmatic BM3050 system 27 August 2019 3. Repairs and adjustments (REP and ADJ)
3-69
REP 10.3 TR-M5 / M6 Blower Motor (Blower Assembly)
Parts List on PL 11.2
Removal
1. Turn off the main power and disconnect the power cord.
2. Undock from BM and SQF (REP 1.0 Undocking BM / TR / SQF).
3. Remove Front and Rear Cover (REP 10.0 Front and Rear Cover).
4. Remove Infeed Cover (REP 10.2 Infeed cover).
5. Open Top Cover.
6. Loosen screws (x2) [A] three turns.
7. Turn crank until the knife beam reach its lowest position [B].
8. Disconnect connectors (x2) and remove the screws (x2) and the nuts (x2) [C].
9. Lift out Fan Assembly [D].
REP 10.4 Upper Exit Cover
Parts List on PL 11.0
Removal
1. Turn off the main power and disconnect the power cord.
2. Undock from BM and SQF (REP 1.0 Undocking BM / TR / SQF or
remove Stacker (REP 8.0 Stacker Module).
3. Remove Front and Rear Cover (REP 10.0 Front and Rear Cover).
4. Loosen front screws (x3) and rear screws (x3) [A].
5. Remove Upper Exit Cover [B].
[A]
[B]
[D]
[B]
Replacement
1. Reverse removal procedure.
Replacement
1. Reverse removal procedure.
[C]
[A]