Plockmatic BM3050 system 27 August 2019 4. Troubleshooting (RAP)
4-104
Fault code indicates that the Side jogger motor BM-M3 has a short circuit.
Procedure
Disconnect the motor plug M3. Enter Service Mode (GP1) and run M3 (GP4).
Fault code BM-011 (Open circuit) is displayed?
Y N
• Disconnect plug C.P2 from MD6DC PCB “C”.
• Check wires for Short circuit across orange wire M3 to C.P2-9 (violet).
• Check wires for Short circuit across the violet wire M3 to C.P2-2 (orange).
• Check for short circuit between wires to chassis.
Is there a short circuit
Y N
Replace MD6DC PCB ”C” (PL 3.0).
Replace/Repair wire Harness.
Replace motor BM-M3 (PL 5.3)
BM-010 Side Jogger Motor BM-M3 Short Circuit