Plockmatic BM3050 system 27 August 2019 3. Repairs and adjustments (REP and ADJ)
3-295
ADJ 12.6 Interlock Switch Slide Door
Adjustment
1. Ensure that the Slide Door Retaining magnet is adjusted so that
the outer surface of the Slide Door is level with the surrounding surface of
the Front Cover (Figure 1).
2. Check / Adjust the Interlock Switch Slide Door Actuator so that
there is 1±0.5mm play in the switch,
when the Slide Door is closed (Figure 1).
Purpose
To ensure that the Interlock Switch Slide Door Actuator is correctly adjusted.
Figure 1 Adjusting Slide Door and Interlock Switch Slide Door Actuator
1. Loosen counter nuts and adjust magnet.
2. Loosen screws (x2) and adjust Actuator.

Table of Contents