Plockmatic BM3050 system 27 August 2019 5. Service tables (GP)
5-18
GP 10 NVM Values
Purpose
This procedure will provide factory settings table as well as instructions on
how to adjust the various values and locations.
Procedure
NOTE:
The EEProm Values are subject to change between S/W releases.
Refer to the Software Release Document for respective software version.
Values in this Table are for BM CPU(A) 1.00 S/W version.
1. Enter Service Mode (GP 1).
2. Select target module.
3. Select item [NVM].
4. Press [up/down] buttons to access desired Index to be changed.
5. Press [±] buttons to change value.
6. Press green check mark to conrm.
7. Press [Go back] to reach XX Service Components menu.
8. Press [Home] to reach Target selection menu.
9. Press [Exit Service] when ready to exit service mode.