Plockmatic BM3050 system 27 August 2019 3. Repairs and adjustments (REP and ADJ)
3-181
REP 13.12 Transportation Disengage Solenoid (CT-SOL4)
Idler Shaft
Parts List on PL 12.27
Removal
1. Turn off the main power and disconnect the power cord.
2. Unlatch and pull out the Slide.
3. Remove tension spring [A].
4. Remove E-clips (x2) [B].
5. Remove Idler Shaft [C].
Replacement
1. Reverse removal procedure.
REP 13.13 Transportation Disengage Solenoid (SOL4)
Mechanism
Replacement
1. Reverse removal procedure.
Parts List on PL 12.27
Removal
1. Turn off the main power and disconnect the power cord.
2. Unlatch and pull out the Slide.
3. Remove Idler Shaft (REP 13.12).
4. Remove screw to release solenoid linkage [A].
5. Remove screws (x2) [B]. Note position of shims between ball bearing and press nuts.
6. Remove Transportation Disengage Solenoid (SOL4) Mechanism [C].
[A]
[B]
[C]
[A][B] [C]