Plockmatic BM3050 system 27 August 2019 3. Repairs and adjustments (REP and ADJ)
3-109
REP 11.15 SQF-Q6 Clamp Sensor
Parts List on PL 10.7
Removal
1. Turn off the main power and disconnect the power cord.
2. Tilt the Machine (REP 11.4 Tilt the Machine).
3. Disconnect connector [A] (x1).
4. Remove screw [B] (x1).
5. Remove sensor [C].
Replacement
1. Reverse removal procedure.
[A][B] [C]
Bottom view
REP 11.16 SQF-M4 Roll Motor & SQF-Q8 (M4) Motor Sensor
Replacement
1. Reverse removal procedure.
NOTE:
Ensure that the encoder disc is not in contact with the motor connectors,
minimum distance approximately 2 mm [ H ]. If not possible, bend the connectors.
Parts List on PL 10.6
Removal
1. Turn off the main power and disconnect the power cord.
2. Remove upper part of the Exit Cover
(REP 11.2 Exit Cover Assembly).
3. Loosen screw [A] (x1).
4. Loosen screw [B] (x1).
5. Remove safety cover [C].
6. Loosen allen screw [D] and remove Encoder Disc [E] (x1).
7. Disconnect connector [F] (x1).
8. Remove sensor [G].
[A]
[B] [C]
[D] [F]
[G]
[E]
min. 2 mm
[H]