Plockmatic BM3050 system 27 August 2019 5. Service tables (GP)
5-32
Possible
to retrieve NVM
values?
NVM tag
available?
NVM tag
available?
Yes
Yes Yes
No
No No
Record critical
NVM values (see
GP 12 & 20) on
a piece of paper
and store in ma-
chine for future
reference
Perform NVM
reset GP 20.
Replace PCB.
Download soft-
ware GP 19.
Perform NVM
reset GP 20.
Replace PCB.
Download soft-
ware GP 19.
Perform Paper
size reset GP 12.
Compare values
with NVM tag and
if different note
the new values
on the tag.
Record critical
NVM values (see
GP 20) on a piece
of paper and
store in machine
for reference.
Need to replace
PCB Controller,
PCB A
continued on next page
GP 20 NVM Reset, continued
Replaced a part
affecting booklet
quality
Record critical
NVM values (see
GP 12) on NVM
tag or a piece of
paper and store
in machine for
future reference.
Perform Paper
size reset GP 12.

Table of Contents