VAR/REF Frequency
Sets the frequency of the VAR signal and the REF signal. As the two signals must
have the same frequency, the setting is valid for both signals.
Remote command:
[:SOURce<hw>]:VOR:VAR:FREQuency on page 634
VAR Depth
Sets the AM modulation depth of the 30Hz VAR signal.
Note: The sum of "Subcarrier depth", "VAR depth" and "COM/ID > Depth" must be
smaller than 100 %.
Remote command:
[:SOURce<hw>]:VOR:VAR[:DEPTh] on page 634
Subcarrier Frequency
Sets the frequency of the FM carrier.
Remote command:
[:SOURce<hw>]:VOR:SUBCarrier[:FREQuency] on page 633
Subcarrier Depth
Sets the AM modulation depth of the FM carrier.
Note: The sum of "Subcarrier depth", "VAR depth" and "COM/ID > Depth" must be
smaller than 100 %.
Remote command:
[:SOURce<hw>]:VOR:SUBCarrier:DEPTh on page 633
REF Deviation
Sets the frequency deviation of the reference signal on the FM carrier.
Remote command:
[:SOURce<hw>]:VOR:REFerence[:DEViation] on page 633