Avionic standards
R&S
®
SMA100B
160User Manual 1178.3834.02 ─ 09
Time Schema
Sets the time schema of the Morse code for the COM/ID signal.
"Standard"
The set dot length determines the length of the dash, the symbol space and letter
space of the Morse code.
"User"
You can set each length value separately.
Remote command:
[:SOURce<hw>]:ILS:LOCalizer:COMid:TSCHema on page 613
Dot Length
Sets the length of a Morse code dot.
If "Time Schema > Standard", the dot length value determines also the length of the
dash (= 3 times the dot length), symbol space (= dot length) and letter space (= 3 times
the dot length).
Remote command:
[:SOURce<hw>]:ILS:LOCalizer:COMid:DOT on page 612
Dash Length
Requires "Time Schema > User".
Sets the length of a Morse code dash.
Remote command:
[:SOURce<hw>]:ILS:LOCalizer:COMid:DASH on page 611
Symbol Space
Requires "Time Schema > User".
Sets the length of the Morse code symbol space.
Remote command:
[:SOURce<hw>]:ILS:LOCalizer:COMid:SYMBol on page 613
Letter Space
Requires "Time Schema > User".
Sets the length of a Morse code letter space.
Remote command:
[:SOURce<hw>]:ILS:LOCalizer:COMid:LETTer on page 613