EasyManua.ls Logo

R&S SMA100B - Source:vor Subsystem

R&S SMA100B
822 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
SMA100B
625User Manual 1178.3834.02 ─ 09
Manual operation: See "Marker Frequency" on page 162
[:SOURce<hw>][:ILS]:MBEacon[:MARKer]:DEPTh <Depth>
Sets the modulation depth of the marker signal for the ILS marker beacon signal.
Parameters:
<Depth> float
Range: 0 to 100
Increment: 0.1
*RST: 95
Example: See Example "Configure and generate an ILS marker beacons
signal" on page 596.
Manual operation: See "Marker Depth" on page 162
[:SOURce<hw>][:ILS]:MBEacon:PRESet
Sets the parameters of the ILS marker beacons component to their default values
(*RST values specified for the commands).
For other ILS preset commands, see [:SOURce<hw>]:ILS:PRESet on page 598.
Example:
SOURce1:ILS:MBEacon:PRESet
Usage: Event
[:SOURce<hw>][:ILS]:MBEacon[:MARKer]:PULSed <Pulsed>
Activates the modulation of a pulsed marker signal (morse coding).
Parameters:
<Pulsed> 1 | ON | 0 | OFF
*RST: 0
Example: See Example "Configure and generate an ILS marker beacons
signal" on page 596.
Manual operation: See "Pulsed Marker" on page 162
14.16.2.5 SOURce:VOR subsystem
Option: R&S SMAB-K25
The SOURce:VOR subsystem contains all commands for configuring the VOR signal.
Characteristics which are valid for all modulations and the LF output are configured in
the SOURce:LFOutput subsystem. The signal is output at the LF connector.
SOURce subsystem

Table of Contents