14.16.2.3 SOURce:ADF subsystem
Option: R&S SMAB-K25
The SOURce:ADF subsystem contains all commands for configuring the ADF signal.
Characteristics which are valid for all modulations and the LF output are configured in
the SOURce:LFOutput subsystem. The signal is output at the LF connector.
Commands
[:SOURce<hw>]:ADF:COMid:CODE................................................................................ 600
[:SOURce<hw>]:ADF:COMid:DASH.................................................................................600
[:SOURce<hw>]:ADF:COMid:DEPTh............................................................................... 601
[:SOURce<hw>]:ADF:COMid:DOT...................................................................................601
[:SOURce<hw>]:ADF:COMid:FREQuency........................................................................601
[:SOURce<hw>]:ADF:COMid:LETTer............................................................................... 601
[:SOURce<hw>]:ADF:COMid:PERiod...............................................................................602
[:SOURce<hw>]:ADF:COMid:SYMBol..............................................................................602
[:SOURce<hw>]:ADF:COMid:TSCHema.......................................................................... 602
[:SOURce<hw>]:ADF:COMid[:STATe]...............................................................................603
[:SOURce<hw>]:ADF:COMid:CODE <Code>
Sets the coding of the COM/ID signal by the international short name of the airport
(e.g. MUC for the Munich airport).
The COM/ID tone is sent according to the selected code, see Chapter D, "Morse code
settings", on page 784.
If no coding is set, the COM/ID tone is sent uncoded (key down).
Parameters:
<Code> string
Example: See Example "Configure and generate a ADF signal"
on page 594.
Manual operation: See "Code" on page 168
[:SOURce<hw>]:ADF:COMid:DASH <Dash>
Sets the length of a Morse code dash.
Parameters:
<Dash> float
Range: 50E-3 to 1
Increment: 1E-4
*RST: 300E-3
Example: See Example "Configure and generate a ADF signal"
on page 594.
Manual operation: See "Dash Length" on page 169
SOURce subsystem

Table of Contents

Other manuals for R&S SMA100B

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S SMA100B and is the answer not in the manual?

R&S SMA100B Specifications

General IconGeneral
BrandR&S
ModelSMA100B
CategoryPortable Generator
LanguageEnglish

Related product manuals