Remote control commands
R&S
®
SMA100B
534User Manual 1178.3834.02 ─ 09
Example:
SENS:SWE:TIME:YSC:MAX 10DBM
Sets 10 dBm as the upper limit of the measurement diagram.
Manual operation: See "Min - Max Level - Power Analysis" on page 263
:SENSe[:POWer]:SWEep:TIME:YSCale:MINimum <Minimum>
Sets the minimum value for the y axis of the measurement diagram.
Parameters:
<Minimum> float
Range: -200 to 100
Increment: 0.01
*RST: dBm
Example:
SENS:SWE:TIME:YSC:MIN -10DBM
Sets -10 dBm as the lower limit of the measurement diagram.
Manual operation: See "Min - Max Level - Power Analysis" on page 263
14.14.5 TRACe subsystem
:TRACe<ch>:FREQ:SWEep:SRC....................................................................................536
:TRACe<ch>:POW:SWEep:SRC..................................................................................... 536
:TRACe<ch>:TIME:SWEep:SRC..................................................................................... 537
:TRACe<ch>[:POWer]:SWEep:COLor..............................................................................537
:TRACe<ch>[:POWer]:SWEep:COPY.............................................................................. 538
:TRACe<ch>[:POWer]:SWEep:DATA:POINts?.................................................................. 538
:TRACe<ch>[:POWer]:SWEep:DATA:XVALues?............................................................... 538
:TRACe<ch>[:POWer]:SWEep:DATA:YSValue?................................................................ 539
:TRACe<ch>[:POWer]:SWEep:DATA:YVALues?............................................................... 539
:TRACe<ch>[:POWer]:SWEep:FEED...............................................................................539
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:AVERage?...................................... 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:HREFerence?..................................540
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:LREFerence?.................................. 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:MAXimum?..................................... 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:MINimum?...................................... 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:PULSe:BASE?................................ 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:PULSe:TOP?.................................. 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:POWer:REFerence?....................................540
:TRACe<ch>[:POWer]:SWEep:MEASurement:PULSe:DCYCle?.........................................540
:TRACe<ch>[:POWer]:SWEep:MEASurement:PULSe:DURation?.......................................540
:TRACe<ch>[:POWer]:SWEep:MEASurement:PULSe:PERiod?..........................................540
:TRACe<ch>[:POWer]:SWEep:MEASurement:PULSe:SEParation?.................................... 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:PULSe:STATe?........................................... 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:TRANsition:NEGative:DURation?..................540
:TRACe<ch>[:POWer]:SWEep:MEASurement:TRANsition:NEGative:OCCurrence?............. 540
:TRACe<ch>[:POWer]:SWEep:MEASurement:TRANsition:NEGative:OVERshoot?...............540
:TRACe<ch>[:POWer]:SWEep:MEASurement:TRANsition:POSitive:DURation?...................540
:TRACe<ch>[:POWer]:SWEep:MEASurement:TRANsition:POSitive:OCCurrence?...............540
Power sensor measurement subsystems