EasyManua.ls Logo

R&S SMA100B - Analog Modulations; Shape; State (LF Frequency Sweep)

R&S SMA100B
822 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Analog modulations
R&S
®
SMA100B
114User Manual 1178.3834.02 ─ 09
The internal LF signal can the modulation signal source for any of the analog mod-
ulations. The LF signal applies to all modulations which use the internal modulation
signal. Therefore, any modification of the LF signal immediately affects all currently
active modulations.
Settings
State (LF frequency sweep)........................................................................................ 114
Shape.......................................................................................................................... 114
Frequency....................................................................................................................116
Period.......................................................................................................................... 116
Pulse Width................................................................................................................. 116
Pulse Duty Cycle......................................................................................................... 116
Triangle Rise............................................................................................................... 117
Trapezoid Rise / Fall....................................................................................................117
Trapezoid High............................................................................................................ 117
State (LF frequency sweep)
Status of the LF frequency sweep signal.
You find this parameter in two dialogs:
"LF Frequency Sweep" turns on/off the signal generation.
See Sweep mode settings for access.
"Analog Modulation Sources" displays the current state (read-only). If it is turned
on, this dialog provides the varying sweep frequency, see Current Frequency.
Note: Active RF frequency, RF level or RF combined sweep modes deactivate the LF
sweep or List mode and vice versa.
Remote command:
[:SOURce<hw>]:LFOutput:FREQuency:MODE on page 656
Shape
Selects the waveform shape of the LF generator signal.
The "Triangle" and "Trapezoid" waveforms require option R&S SMAB-K24.
"Sine"
1 = Period
Modulation settings

Table of Contents

Other manuals for R&S SMA100B

Related product manuals