The R&S SMA100B supplies the signal at the V/GHz X-Axis connector.
"0,25 V/GHz" /
" 0,5 V/GHz" / "
1 V/GHz"
Supplies the voltage proportional to the set frequency, derived from
the selected setting.
"X-Axis"
Supplies a voltage range from 0 V to 10 V proportional to the fre-
quency sweep range, set with Start Frequency/Stop Frequency.
Remote command:
:OUTPut:FPRoportional:SCALe on page 491
Marker / User
Option: R&S SMAB-B28
Selects the signal to be supplied at the Marker User1 connector.
"Marker"
Assigns a marker signal to the output.
To configure and assign the marker signals, see Chapter 7.5.5, "Edit
marker settings", on page 199.
"User"
Intended for future use.
Remote command:
:OUTPut:USER:MARKer on page 492