EasyManua.ls Logo

R&S SMA100B - Calculate Subsystem

R&S SMA100B
822 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Remote control commands
R&S
®
SMA100B
494User Manual 1178.3834.02 ─ 09
Power and Pulse Data Analysis, Gated Measurements (option R&S SMA100B-
K28)
The power analysis measurement commands are subsumed under the
SENSe[:POWer]:SWEep:… commands. Three measurement modes are available:
Frequency, Power and Time.
The power analysis measurement is started with the
SENSe[:POWer]:SWEep:INITiate command and the measurement result retrieved
with the TRACe[:POWer]:SWEep:… commands.
The four sensors are distinguished by the suffix at the second key word SENSe.
The time gate settings are performed using the CALCulate[:POWer]:SWEep:… com-
mands.
The measurement diagram and results can be stored in a hardcopy with the
SENSe[:POWer]:SWEep:HCOPy:… commands.
General parameter and measurement settings are valid for all connected sensors,
therefore, no suffix is used in these commands.
14.14.1 CALCulate subsystem
:CALCulate[:POWer]:SWEep:FREQuency:MATH<ch>:STATe.............................................494
:CALCulate[:POWer]:SWEep:FREQuency:MATH<ch>:SUBTract........................................ 495
:CALCulate[:POWer]:SWEep:FREQuency:MATH<ch>:XVAL.............................................. 495
:CALCulate[:POWer]:SWEep:FREQuency:MATH<ch>:YVAL.............................................. 495
:CALCulate[:POWer]:SWEep:POWer:MATH<ch>:STATe....................................................496
:CALCulate[:POWer]:SWEep:POWer:MATH<ch>:SUBTract............................................... 496
:CALCulate[:POWer]:SWEep:POWer:MATH<ch>:XVAL..................................................... 497
:CALCulate[:POWer]:SWEep:POWer:MATH<ch>:YVAL..................................................... 497
:CALCulate[:POWer]:SWEep:TIME:GATE<ch>:AVERage?.................................................497
:CALCulate[:POWer]:SWEep:TIME:GATE<ch>:FEED........................................................498
:CALCulate[:POWer]:SWEep:TIME:GATE<ch>:MAXimum?................................................498
:CALCulate[:POWer]:SWEep:TIME:GATE<ch>:STARt....................................................... 499
:CALCulate[:POWer]:SWEep:TIME:GATE<ch>:STOP........................................................499
:CALCulate[:POWer]:SWEep:TIME:GATE<ch>:STATe....................................................... 499
:CALCulate[:POWer]:SWEep:TIME:MATH<ch>:STATe.......................................................499
:CALCulate[:POWer]:SWEep:TIME:MATH<ch>:SUBTract.................................................. 500
:CALCulate[:POWer]:SWEep:TIME:MATH<ch>:XVAL........................................................500
:CALCulate[:POWer]:SWEep:TIME:MATH<ch>:YVAL........................................................500
:CALCulate[:POWer]:SWEep:FREQuency:MATH<ch>:STATe <State>
Activates the trace mathematics mode for "Frequency" measurement. This feature
enables you to calculate the difference between the measurement values of two
traces. For further calculation, a math result can also be assigned to a trace.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: 0
Power sensor measurement subsystems

Table of Contents

Other manuals for R&S SMA100B

Related product manuals