RF signal configuration
R&S
®
SMA100B
68User Manual 1178.3834.02 ─ 09
Before setting the parameters and activating the phase continuous mode, turn off aci-
tive sweeps.
1. If the "RF Frequency Sweep" is running, select "Sweep" > "RF Frequency Sweep".
2. Turn off "State".
3. On the home screen, select "Frequency" > "Phase".
4. Turn off "Phase Continuous Active", if enabled.
5. Select "Frequency Range" > "Narrow".
6. Check if the range displayed in "Frequency Range From" and "To", corresponds to
your range selection.
7. IF the displayed frequency range does not correspond to the selection, select "Fre-
quency Range > Wide" (requires option R&S SMAB-B711).
8. If the dipslayed range corresponds to the selection, enable "Phase Continuous
Active".
9. In the "RF Frequency Sweep" dialog
a) Modify the "Start Freq" and "Stop Freq" or "Center Frequency" and "Span" as
needed.
b) Set the RF frequency sweep state to “ON”.
To set a phase continuous frequency sweep
1. On the home screen, select "Sweep" > "RF Frequency Sweep" > "Frequency
Range".
2. Set the "Start Frequency" and "Stop Frequency" or "Center Frequency" and "Span"
for the sweep range.
3. In the "General" tab, configure the sweep parameters as required.
4. Turn on "State" to start the sweep signal generation.
4.4 RF connector settings
Access:
1. Select "Frequency" > "RF Connectors".
RF connector settings