Parameters
List of Parameters
1-102
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Specifies the interfaces which can be used to change parameters.
This parameter allows the user to easily protect the inverter from unauthorized modification of parameters.
Annotation: Parameter P0927 is not password protected.
Example: Default: All bits are set:
The default setting allows parameters to be changed via any interface.
Description: Displays the total number of messages available
Description: Displays fault history.
Index: [0] = Recent fault trip --, fault 1
[1] = Recent fault trip --, fault 2
[2] = Recent fault trip --, fault 3
[3] = Recent fault trip --, fault 4
[4] = Recent fault trip --, fault 5
[5] = Recent fault trip --, fault 6
[6] = Recent fault trip --, fault 7
[7] = Recent fault trip --, fault 8
[8] = Recent fault trip -1, fault 1
Dependency: Index 1 used only if second fault occurs before first fault is acknowledged.
Note: See Chapter "Faults and Warnings".
p0927 Parameter changeable via / Change par. via
CU240S DP
CU240S DP-F
CU240S PN
Access level: 2 P-Group: Communications Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 1111 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Fieldbus Yes No -
01 BOP Yes No -
02 USS on RS232 Yes No -
r0944 Total number of messages / Total nb Mes
Access level: 3 P-Group: Messages Data type: Unsigned16
Unit: - Data set: -
r0947[0...63] CO: Last fault code / Last fault code
CU240E
CU240S
CU240S DP
CU240S PN
Access level: 2 P-Group: Messages Data type: Unsigned16
Unit: - Data set: -