Command and Drive Data Sets – Overview
Parameters
1-299
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
1.3 Command and Drive Data Sets – Overview
1.3.1 Command Data Sets (CDS)
p0700[0...2] Selection of command source / Command source sel
p0701[0...2] Function of digital input 0 / Function of DI0
p0702[0...2] Function of digital input 1 / Function of DI1
p0703[0...2] Function of digital input 2 / Function of DI2
p0704[0...2] Function of digital input 3 / Function of DI3
p0705[0...2] Function of digital input 4 / Function of DI4
p0706[0...2] Function of digital input 5 / Function of DI5
p0707[0...2] Function of digital input 6 / Function of DI6
p0708[0...2] Function of digital input 7 / Function of DI7
p0709[0...2] Function of digital input 8 / Function of DI8
p0712[0...2] Analog / digital input 0 / Ana/digi input 0
p0713[0...2] Analog / digital input 1 / Ana/digi input 1
p0719[0...2] Selection of cmd. & freq. setp. / Cmd.&freq.setp.sel
p0727[0...2] Selection of 2/3-wire method / 2/3-wire selection
p0731[0...2] BI: Function of digital output 0 / Fct. of DO0
p0732[0...2] BI: Function of digital output 1 / Fct. of DO1
p0733[0...2] BI: Function of digital output 2 / Fct. of DO2
p0800[0...2] BI: Download parameter set 0 / Dwnl.par.set 0
p0801[0...2] BI: Download parameter set 1 / Dwnl.par.set 1
p0840[0...2] BI: ON/OFF1 / ON/OFF1
p0842[0...2] BI: ON reverse/OFF1 / BI:ON reverse/OFF1
p0844[0...2] BI: 1. OFF2 / 1. OFF2
p0845[0...2] BI: 2. OFF2 / 2. OFF2
p0848[0...2] BI: 1. OFF3 / 1. OFF3
p0849[0...2] BI: 2. OFF3 / 2. OFF3
p0852[0...2] BI: Pulse enable / Pulse enable
p1000[0...2] Selection of frequency setpoint / Freq setp. select.
p1020[0...2] BI: Fixed freq. selection Bit 0 / FF sel. Bit 0
p1021[0...2] BI: Fixed freq. selection Bit 1 / FF sel. Bit 1
p1022[0...2] BI: Fixed freq. selection Bit 2 / FF sel. Bit 2
p1023[0...2] BI: Fixed freq. selection Bit 3 / FF sel. Bit 3
p1023[0...2] BI: Fixed freq. selection Bit 3 / FF sel. Bit 3
p1035[0...2] BI: Enable MOP (UP-command) / Enable MOP(UP)
p1036[0...2] BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
p1041[0...2] BI: MOP select setpoint automatically/manually / Setp. auto/manu
p1042[0...2] CI: MOP auto setpoint / MOP auto setpoint
p1043[0...2] BI: MOP accept rampgenerator setpoint / MOP acc RFG setpo
p1044[0...2] CI: MOP rampgenerator setpoint / MOP RFG setpoint
p1055[0...2] BI: Enable JOG right / Enable JOG ->
p1056[0...2] BI: Enable JOG left / Enable JOG <-
p1070[0...2] CI: Main setpoint / Main setpoint
p1071[0...2] CI: Main setpoint scaling / Main setp scal
p1074[0...2] BI: Disable additional setpoint / Disab.add.setp
p1075[0...2] CI: Additional setpoint / Add. setpoint
p1076[0...2] CI: Additional setpoint scaling / Add. setp.scal
p1110[0...2] BI: Inhibit neg. freq. setpoint / Inh. neg. setp

Table of Contents

Other manuals for Siemens CU240S DP-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240S DP-F and is the answer not in the manual?

Siemens CU240S DP-F Specifications

General IconGeneral
BrandSiemens
ModelCU240S DP-F
CategoryControl Unit
LanguageEnglish

Related product manuals