Parameters
List of Parameters
1-138
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Defines command source of RFG start command (RFG: ramp function generator).
If binary input is equal to zero then the RFG output is held at its present value.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Description: Defines command source of RFG start command (RFG: ramp function generator).
If binary input is equal to zero then the RFG output is held at its present value.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Description: Defines command source of RFG enable setpoint command (RFG: ramp function generator).
If binary input is equal to zero then the RFG input will be set to zero and the RFG output will ramp-down to zero.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Description: Defines command source of RFG enable setpoint command (RFG: ramp function generator).
If binary input is equal to zero then the RFG input will be set to zero and the RFG output will ramp-down to zero.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Description: Defines command source of RFG enable setpoint command (RFG: ramp function generator).
If binary input is equal to zero then the RFG input will be set to zero and the RFG output will ramp-down to zero.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
p1141[0...2] BI: RFG start / RFG start
CU240S DP
CU240S DP-F
Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 2090.5
p1141[0...2] BI: RFG start / RFG start
CU240S PN Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 8890.5
p1142[0...2] BI: RFG enable setpoint / RFG enable setp
CU240E
CU240S
Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 1
p1142[0...2] BI: RFG enable setpoint / RFG enable setp
CU240S DP
CU240S DP-F
Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 2090.6
p1142[0...2] BI: RFG enable setpoint / RFG enable setp
CU240S PN Access level: 3 P-Group: Commands Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 8890.6