Function diagrams
Overview
2-322
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Fig. 2-3 1200 – Connection of External and Internal Setpoints
- 1200 -
Function diagram
87654321
1200_BICO_Overv.vsd
Overview
SINAMICS G120
02.04.2007 V3.0
Connection of External and Internal Setpoints
r0755 [2]
CO:AI scal[4000h]
.
.
.
.
.
.
.
.
.
MOP
PID
MOP
FF
FF
PID
0
1
SUM
USS
on RS232
Fieldbus
USS
on RS485
BOP
AO
AI
DO
DI
0
0
1
0
Sequence
control
AFM
RFG
V/f
FOC
Imax contr.
SUM/JOG
selection
PID
controller
Bin.inp.val
r0722
r0722
(52.3)
Fct. of DO0
P0731.CDS
AO
(21[0])
P0771 [2]
BOP CtrlWd
r0019
r0019
r2018 [8]
PZD<-COM(USS)
CtrlWd 1 <- COM
r2036
CtrlWd2 <- COM
r2037
PZD->COM (USS)
(0)
P2019 [8]
r2050 [8]
PZD from FB
CtrlWd1 <- FB
r2090
CtrlWd2 <- FB
r2091
PZD to FB
(0)
P2051 [8]
r2015 [8]
PZD<-USS
CtrlWd1 <- USS
r2032
CtrlWd2 <- USS
r2033
PZD->USS
(0)
P2016 [8]
(0)
Enable JOG ->
P1055.CDS
(0)
Enable JOG <-
P1056.CDS
(19.13)
Enable MOP(UP)
P1035.CDS
(19.14)
Enable MOP(DWN)
P1036.CDS
(722.3)
FF sel. Bit 0
P1020.CDS
(722.4)
FF sel. Bit 1
P1021.CDS
(722.5)
FF sel. Bit 2
P1022.CDS
(722.6)
FF sel. Bit 3
P1023.CDS
(722.3)
BI:PID setp->Bit 0
P2220.CDS
(722.4)
BI:PID setp->Bit 1
P2221.CDS
(722.5)
BI:PID setp->Bit 2
P2222.CDS
(722.6)
BI:PID setp->Bit 3
P2223.CDS
(19.13)
PID-MOP (UP)
P2235.CDS
(19.14)
PID-MOP (DWN)
P2236.CDS
r1050
MOP outp.freq. [Hz]
r1024
Act. FF [Hz]
r2224
Fixed.PID setp [%]
r2250
PMOP outp. setp [%]
Add. Setpoint
(0)
P1075.CDS
Add. setp.scal
(1)
P1076.CDS
Main setp scal
(1)
P1071.CDS
Main setpoint
(755[1])
P1070.CDS
(0)
Disab.add.setp
P1074.CDS
PID setpoint
(0)
P2253.CDS
CI:PID trim source
(0)
P2254.CDS
PID feedback
(755[0])
P2264.CDS
(0)
Enab. PID ctrl
P2200.CDS
r1078
Tot. freq.setp [Hz]
r2294
Act.PID output [%]
JOG frequency
0.00 ... 650.00 [Hz]
P1058.DDS (5.00)
JOG frequency <-
0.00 ... 650.00 [Hz]
P1059.DDS (5.00)
(0)
Inh. neg. setp
P1110.CDS
(722.1)
Reverse
P1113.CDS
(1)
RFG enable
P1140.CDS
(722.0)
ON/OFF1
P0840.CDS
(0)
BI:ON reverse/OFF1
P0842.CDS
(1)
1. OFF2
P0844.CDS
(19.1)
2. OFF2
P0845.CDS
(1)
1. OFF3
P0848.CDS
(1)
2. OFF3
P0849.CDS
(1)
Pulse enable
P0852.CDS
Act StatWd1
r0052
r0052
Act StatWd2
r0053
r0053
Act CtrlWd1
r0054
r0054
Act CtrlWd2
r0055
r0055
JOG Enable
0000 bin ... 0001 bin
P1057 (0001 bin)
0
0
1
1

Table of Contents

Other manuals for Siemens CU240S DP-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240S DP-F and is the answer not in the manual?

Siemens CU240S DP-F Specifications

General IconGeneral
BrandSiemens
ModelCU240S DP-F
CategoryControl Unit
LanguageEnglish

Related product manuals