Description: Sets compensation time of gating unit interlock.
Description: To control the Voltage-/current correction.
Voltage- and current correction can be enabled/disabled separately (output filter).
Description: Alpha component of the voltage correction value (output filter installed and vector control active).
Description: Beta component of the voltage correction value (output filter installed and vector control active).
Description: Alpha component of the current correction (output filter installed and vector control active).
Description: Beta component of the current correction (output filter installed and vector control active).
p1828 Gating unit dead time / Gating dead time
Access level: 4 P-Group: Modulation Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
0.00 [µs] 3.98 [µs] 0.01 [µs]
p1860 Filter control word / Filter control wor
Access level: 3 P-Group: Commands Data type: Unsigned16
Quick comm. NO Active: YES Data set: -
Can be changed: U, T
Min Max Factory setting
- - 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Filter correction on/off Yes No -
01 Voltage correction on/off Yes No -
02 Current correction on/off Yes No -
r1861 Filter correction voltage (alpha-component) / Filter correction
Access level: 2 P-Group: - Data type: Floating Point
Unit: [V] Data set: -
r1862 Filter correction voltage (beta-component) / Filter correction
Access level: 2 P-Group: - Data type: Floating Point
Unit: [V] Data set: -
r1863 Filter correction current (alpha-component) / Filter correction
Access level: 2 P-Group: - Data type: Floating Point
Unit: [A] Data set: -
r1864 Filter correction current (beta-component) / Filter correction
Access level: 2 P-Group: - Data type: Floating Point
Unit: [A] Data set: -

Table of Contents

Other manuals for Siemens CU240S DP-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240S DP-F and is the answer not in the manual?

Siemens CU240S DP-F Specifications

General IconGeneral
BrandSiemens
ModelCU240S DP-F
CategoryControl Unit
LanguageEnglish

Related product manuals