EasyManua.ls Logo

Siemens CU240S DP-F - p1036[0...2] BI: Enable MOP (DOWN-command); Enable MOP(DWN)

Siemens CU240S DP-F
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-121
ยฉ Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Defines source for motor potentiometer setpoint decrease frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator decelerates with the rate of P1048.
Description: Defines source for motor potentiometer setpoint decrease frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator decelerates with the rate of P1048.
Description: Defines source for motor potentiometer setpoint decrease frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator decelerates with the rate of P1048.
p1036[0...2] BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
CU240E
CU240S
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 19.14
p1036[0...2] BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
CU240S DP
CU240S DP-F
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 2090.14
p1036[0...2] BI: Enable MOP (DOWN-command) / Enable MOP(DWN)
CU240S PN Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 8890.14

Table of Contents

Other manuals for Siemens CU240S DP-F

Related product manuals