List of Parameters
Parameters
1-179
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Enters integral time of current controller.
Description: Displays actual output of Isq current (torque current) controller (PI controller).
It contains the proportional and integral part of the PI controller.
Description: Displays integral output of Isq current (torque current) controller (PI controller).
Description: Displays actual output of Isd current (flux current) controller (PI controller).
It contains the proportional and integral part of the PI controller.
Description: Displays integral output of Isd current (flux current) controller (PI controller).
Description: Displays limit of integral output voltage setpoint of Isd current controller.
Description: Displays actual output voltage setpoint of cross channel decoupling.
Description: Sets oscillation damping gain for sensorless vector control at low frequencies. The oscillation damping subtracts
the result of a delayed differential (DT1) from the setpoint frequency.
p1717[0...2] Integral time current controller / Int.time cur. ctrl
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
1.0 [ms] 50.0 [ms] 4.1 [ms]
r1718 CO: Output of Isq controller / Outp. Isq ctrl
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1719 CO: Integral output of Isq ctrl. / Int. outp. Isq
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1723 CO: Output of Isd controller / Outp. Isd ctrl
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1724 CO: Integral output of Isd ctrl. / Int. outp. Isd
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1725 CO: Integral limit of Isd ctrl. / Int. limit Isd
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
r1728 CO: Decoupling voltage / Decoupl. volt
Access level: 4 P-Group: Closed-loop control Data type: Floating Point
Unit: [V] Data set: -
p1740 Gain for oscillation damping / Oscill. damp. gain
Access level: 3 P-Group: Closed-loop control Data type: Floating Point
Quick comm. NO Active: YES Data set: -
Can be changed: U, T
Min Max Factory setting
0.000 10.000 0.000