Parameters
List of Parameters
1-120
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Inhibits reverse setpoint selection of the MOP.
Values: 0: Reverse direction is allowed
1: Reverse direction inhibited
Note: It is possible to change motor direction using the motor potentiometer setpoint (increase / decrease frequency
either by using digital inputs or OP keypad up / down (e.g. BOP)).
The "reversing key" of the OP (e.g. BOP) is not affected by the settings of P1032. Use P1110 to fully prevent
change of motor direction.
Setting 0 enables a change of motor direction using the motor potentiometer setpoint (increase/decrease fre-
quency).
Description: Defines source for motor potentiometer setpoint increase frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator accelerates with the rate of P1047.
Description: Defines source for motor potentiometer setpoint increase frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator accelerates with the rate of P1047.
Description: Defines source for motor potentiometer setpoint increase frequency.
Dependency: When Standard Telegram selected (P0700 = 6, P0922 = Standard Telegram), parameter cannot be changed.
Notice: If this command is enabled by short pulses of less than 1 second, the frequency is changed in steps of 0.1 Hz.
When the signal is enabled longer than 1 second the ramp generator accelerates with the rate of P1047.
p1032 Inhibit reverse direction of MOP / Inhib. MOP reverse
Access level: 2 P-Group: Setpoints Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: T
Min Max Factory setting
0 1 1
p1035[0...2] BI: Enable MOP (UP-command) / Enable MOP(UP)
CU240E
CU240S
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 19.13
p1035[0...2] BI: Enable MOP (UP-command) / Enable MOP(UP)
CU240S DP
CU240S DP-F
Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 2090.13
p1035[0...2] BI: Enable MOP (UP-command) / Enable MOP(UP)
CU240S PN Access level: 3 P-Group: Setpoints Data type: Unsigned32
Quick comm. NO Active: NO Data set: CDS
Can be changed: T
Min Max Factory setting
- - 8890.13