EasyManuals Logo

Siemens CU240S DP-F Parameter Manual

Siemens CU240S DP-F
418 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #362 background imageLoading...
Page #362 background image
Function diagrams
V/f Control
2-362
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Fig. 2-37 6100 – Overview of V/f Control for inverter with PM240
CO/BO:Stat MotCtrl
r0056
r0056
Voltage output to
modulator
n/f(max) +
control reserve
Frequency output to
modulator
active
active
Imax voltage ctrl.
P1345
P1346
Imax frequency ctrl.
P1340
P1341
Imax controller setpoint
Current feedback
Motor temperature
Inverter temperature
PID trim
from AFM
- 6100 -
Function diagram
87654321
6100_V_f.vsd
V/f Control
SINAMICS G120
02.04.2007 V3.0
Overview of V/f Control SINAMICS G120 PM240
+
+
+
+
+
RFG
+
19
6
+
i
2
t
f(V
DC
)
FP 4600
.13
inverter
P1300
V/f characteristic
+
FCC
+
Voltage boost
P1310 ... P1312
P1200
Flying start
P1240
Vdmax
controller
P1335
Slip
compensation
P1338
Resonance
damping
Control mode
0 ... 23
P1300.DDS (0)
Rated mot. current
0.01 ... 10000.00 [A]
P0305.DDS (1.86)
Motor ovl fact [%]
10.0 ... 400.0 [%]
P0640.DDS (200.0)
r1119
Setp before RFG [Hz]
r1170
Setp. after RFG [Hz]
r0063
Act. frequency [Hz]
r1343
CO:Imax ctrl Foutp [Hz]
r1344
CO:Imax ctrl Voutp [V]
r0024
Act. outp. freq [Hz]
r0067
Outp cur limit [A]
r0025
Act.outp. volt [V]
r0068
Output current [A]
Voltage setp.
(0)
P1330.CDS
3
4
P1350
Voltage
build-up

Table of Contents

Other manuals for Siemens CU240S DP-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240S DP-F and is the answer not in the manual?

Siemens CU240S DP-F Specifications

General IconGeneral
BrandSiemens
ModelCU240S DP-F
CategoryControl Unit
LanguageEnglish

Related product manuals