Description: Upper limit threshold value 1 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Lower limit threshold value 1 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Upper limit threshold value 2 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Lower limit threshold value 2 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
Description: Upper limit threshold value 3 for comparing actual torque.
Note: See P2182 (belt threshold frequency 1).
p2185[0...2] Upper torque threshold 1 / Upper trq. thresh1
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 99999.0 [Nm]
p2186[0...2] Lower torque threshold 1 / Lower trq. thresh1
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 0.0 [Nm]
p2187[0...2] Upper torque threshold 2 / Upper trq. thresh2
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 99999.0 [Nm]
p2188[0...2] Lower torque threshold 2 / Lower trq. thresh2
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 0.0 [Nm]
p2189[0...2] Upper torque threshold 3 / Upper trq. thresh3
Access level: 2 P-Group: Messages Data type: Floating Point
Quick comm. NO Active: YES Data set: DDS
Can be changed: U, T
Min Max Factory setting
0.0 [Nm] 99999.0 [Nm] 99999.0 [Nm]