List of Parameters
Parameters
1-295
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Defines the PROFIsafe destination address for the communication.
The PROFIsafe destination address is identical to the PROFIBUS address by default.
This parameter can be changed via a user-entered value.
Note: Valid PROFIsafe address settings:
1 ... 65534
0: default, forces PROFIsafe address to be identical with the PROFIBUS address.
If the PROFIsafe destination address is set manually to a value which is unequal to the PROFIBUS address, it will
not be automatically adjusted when the PROFIBUS address is changed.
This applies when the PROFIBUS address is set via DIP switches as well as via parameter p0918.
Description: Double of parameter p9650. See there.
Note: The debounce delay time in p9850 is entered in seconds!
Description: Double of parameter p9651. See there.
Note: The filter delay time in p9851 is entered in seconds!
Description: Double of parameter p9680. See there.
Note: The delay time in p9880 is entered in seconds!
Description: Double of parameter p9681. See there.
p9810 PROFIsafe destination address / F dest address
CU240S DP-F Access level: 2 P-Group: Communications Data type: Unsigned16
Quick comm. NO Active: NO Data set: -
Can be changed: T
Min Max Factory setting
0 65534 0
p9850 SI Safe Digital Input debounce delay time / SI Debounce FDI
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0.000 [s] 2.000 [s] 0.050 [s]
p9851 SI Safe Digital Input filter delay time / SI Filt. time FDI
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0.000 [s] 0.100 [s] 0.005 [s]
p9880 SI braking ramp delay / SI braking delay
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0.010 [s] 99.000 [s] 0.250 [s]
p9881 SI braking ramp down time / SI ramp down time
CU240S DP-F Access level: 3 P-Group: Safety Integrated Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: -
Min Max Factory setting
0.100 [s] 99.000 [s] 10.000 [s]

Table of Contents

Other manuals for Siemens CU240S DP-F

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens CU240S DP-F and is the answer not in the manual?

Siemens CU240S DP-F Specifications

General IconGeneral
BrandSiemens
ModelCU240S DP-F
CategoryControl Unit
LanguageEnglish

Related product manuals