List of Parameters
Parameters
1-277
© Siemens AG 2007 All Rights Reserved
SINAMICS G120 Control Units CU240S, Edition 05/2007
Description: Defines inputs of Comparator 2, output is P2888.
Index: [0] = Connector input 0 (CI 0)
[1] = Connector input 1 (CI 1)
Dependency: P2802[13] is active level for the Comparator.
Description: Displays result bit of Comparator 2.
Dependency: P2802[13] is active level for the Comparator.
Description: Fixed percent setting 1.
Description: Fixed percent setting 2.
Description: Defines the source to release the wobble function.
p2887[0...1] CI: CMP 2 / CMP 2
Access level: 3 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
- - 755[0]
r2888.0 BO: CMP 2 / CMP 2
Access level: 3 P-Group: Technology Data type: Unsigned16
Unit: - Data set: -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Output of BO Yes No -
p2889 CO: Fixed setpoint 1 in [%] / Fixed setp 1 %
Access level: 3 P-Group: Technology Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
-200.00 [%] 200.00 [%] 0.00 [%]
p2889
p2890
Connector Setting in %
Range : -200% ... 200%
p2890 CO: Fixed setpoint 2 in [%] / Fixed setp 2 %
Access level: 3 P-Group: Technology Data type: Floating Point
Quick comm. NO Active: NO Data set: -
Can be changed: U, T
Min Max Factory setting
-200.00 [%] 200.00 [%] 0.00 [%]
p2940 BI: Release Wobble function / Rel Wobble
Access level: 2 P-Group: Technology Data type: Unsigned32
Quick comm. NO Active: NO Data set: -
Can be changed: T
Min Max Factory setting
- - 0